TROUBLESHOOTING GUIDE
PROBLEM CAUSE CORRECTION
U.V. lamp will not light Check input voltage if below Install a voltage regulator
or above 120 volts
or outlet defective Line cord disconnected Check, replace
Defective U.V. lamp Replace
Defective lamp ballast Check output voltage
Replace ballast
Loose open-circuit wire Trace out and repair
Leak at quartz nipple Defective or cracked O-Ring Replace O-Ring
O-Ring not seated properly Replace O-Ring
OPTIONAL
FEATURES:
U.V. SENSOR WITH AUDIBLE ALARM:
Units with this option require a separate power source. This unit can be added at anytime. It features
a built-in audible alarm and fail-safe circuitry designed to activate a solenoid valve when dosage falls
below a preset level. This is a proprietary true U.V. monitor and control system.